Click to Print Page
 
   
Performance Results
 
GVP-C400
GVP-S350
GVP-S200
Solar Transmittance
80
50
53
Solar Absorptance
14
44
40
Solar Reflectance
6
6
6
Visible Light
Transmission
90
31
33
Visible Light
Absorptance
2
64
62
Visible Light
Reflectance (Exterior)
8
5
5
Visible Light
Reflectance (Interior)
8
6
6
Emmissivity
0.91
0.86
0.87
U-Value (Summer)
1.08
0.96
0.97
U-Value (Winter)
1.14
1.03
1.04
Shading Coefficient
0.97
0.74
0.75
Solar Heat
Gain Coefficient
0.83
0.65
0.66
UV Transmittance
(300-350 Nanos)%
<2
<2
<2
Total Solar
Energy Rejected
17
36
35
Physical and Thermal Properties
 
GVP-C400
GVP-S350
GVP-S200
Tensile Strength
ASTM D 882 (PSI)
30,000
30,000
30,000
Elongation At Break
ASTM D 882 (%)
160
160
160
Yield Stress (5%)
ASTM D 882 (PSI)
15,750
15,750
15,750
Break Strength (lbs./in.)
122
122
122
Yield Strength (5%) (lbs./in.)
64
64
64
Tear Strength ASTM
D 1004 Graves
Tear Test (Initial)
6.8
6.8
6.8
Tensile Modulus
ASTM D 882 (PSI)
558,000
558,000
558,000
Puncture Strength
ASTM D 4830 (lbs.)
71
71
71
Peel Strength
(grams/inch of width)
3,300
3,300
3,300
Poisson's Ratio
ASTM D 882
0.40
0.40
0.40
Abrasion Resistance (%)
ASTM D 1003-92
ASTM D 1044
100 Cycles
<5
<5
<5
ANZI Z 97.1
Pass
Pass
Pass
CPSC CFR 1201,
Category II
Fail
Fail
Fail
GSA Security Criteria
Performance Condition
Daylight Application
(4 PSI / 28 PSI/msec)
3b
3b
3b
BS 6206, Class C
Pass
Pass
Pass
Flame Spread Index
ASTM D 882
2
2
2
Smoke Index
ASTM D 882
31
31
31
Flash Temperature (°F)
ASTM D 1929
735
735
735
Combustion Rate
NEGLIGIBLE
NEGLIGIBLE
NEGLIGIBLE
Melting Point (°C)
263
263
263
Self Ignition (°F)
ASTM D 1929
755
755
755
 
Notes: This test data contains results arrived at only after employing specific test procedures and standards. The included data does not constitute a recommendation for, endorsement of, or certification of the product or material tested. This data is provided for informational purposes only. ShatterGARD Safety & Security Window Films, Inc. makes no representation or warranty, expressed or implied, including the implied warranties of merchantability or fitness for a particular purpose, that its products will conform to these test data. Extrapolation of data from the sample or samples relating to the batch or lot from which data were obtained may not correlate and should be interpreted accordingly with caution. ShatterGARD shall not be responsible for variations in quality, composition, appearance, performance, or other feature of similar subject matter produced by persons or under conditions over which ShatterGARD has no control. Performance results were generated from testing 1/8" (3mm) thick clear glass and are subject to variations within industry standards.
 
Click to Print this Page